{"id":5894,"date":"2020-06-15T14:49:16","date_gmt":"2020-06-15T21:49:16","guid":{"rendered":"https:\/\/up.physicaldiagnosispdx.com\/up\/?page_id=5894"},"modified":"2020-10-29T17:00:15","modified_gmt":"2020-10-30T00:00:15","slug":"pulsus-bisferiens","status":"publish","type":"page","link":"https:\/\/up.physicaldiagnosispdx.com\/up\/cardiology-multimedia-new\/pulsus-bisferiens\/","title":{"rendered":"Pulsus bisferiens"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">[vc_row css=&#8221;.vc_custom_1592155698727{background-color: #fff9f9 !important;}&#8221;][vc_column][vc_column_text]<span style=\"font-size: 14pt;\">Pulsus bisferiens describes the presence of an exaggerated \u201cdouble pulsation\u201d in the arterial pulse. While the arterial pulse is normally dicrotic, consisting of a percussion wave and a tidal wave, the individual waves are not typically visible or palpable at the bedside. The pulse looks and feels like a single wave. When the two waves are discernable at the bedside, it is known as pulsus bisferiens. It is most often associated with the combination of aortic stenosis and aortic regurgitation, but is sometimes seen in patients with pure aortic regurgitation.<\/span><\/p>\n<p>&nbsp;<br \/>\n<figure id=\"attachment_1658\" aria-describedby=\"caption-attachment-1658\" style=\"width: 150px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/up.physicaldiagnosispdx.com\/up\/cardiology-2\/card-tutorial\/#Pulsus_bisferiens\"><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-1658 size-thumbnail\" src=\"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-content\/uploads\/iconfinder_3_1250308-150x150.png\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-content\/uploads\/iconfinder_3_1250308-150x150.png 150w, https:\/\/up.physicaldiagnosispdx.com\/up\/wp-content\/uploads\/iconfinder_3_1250308-300x300.png 300w, https:\/\/up.physicaldiagnosispdx.com\/up\/wp-content\/uploads\/iconfinder_3_1250308.png 512w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><figcaption id=\"caption-attachment-1658\" class=\"wp-caption-text\">&nbsp;<\/figcaption><\/figure>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h1 id=\"patient1\">Patient 1:<\/h1>\n<p><span style=\"font-size: 14pt;\">This is an older man with an aortic root aneurysm complicated by moderate to severe aortic regurgitation. Notice that there is a &#8220;double&#8221; flicker of the swab, illustrating a &#8220;double pulsation&#8221; or bisferiens pulse. <\/span><\/p>\n<p><span style=\"font-size: 14pt;\">This patient also has a <a href=\"https:\/\/up.physicaldiagnosispdx.com\/up\/cardiology-2\/cardiology-multimedia-new\/aortic-regurgitation-2\/#patient2\" target=\"_blank\" rel=\"noopener noreferrer\">decrescendo diastolic murmur over Erb&#8217;s point<\/a>, <a href=\"https:\/\/up.physicaldiagnosispdx.com\/up\/cardiology-2\/cardiology-multimedia-new\/corrigans-pulse\/#patient1\" target=\"_blank\" rel=\"noopener noreferrer\">Corrigan&#8217;s pulse<\/a>, and a<a href=\"https:\/\/up.physicaldiagnosispdx.com\/up\/cardiology-2\/cardiology-multimedia-new\/bounding-pulse\/#patient3\" target=\"_blank\" rel=\"noopener noreferrer\"> bounding peripheral pulse.<\/a><\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1592155788700{background-color: #dcd9dd !important;}&#8221;][vc_column][vc_column_text]\n<p style=\"text-align: center;\"><iframe loading=\"lazy\" src=\"https:\/\/player.vimeo.com\/video\/472433660?loop=1\" width=\"320\" height=\"550\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\">&amp;lt;span data-mce-type=&#8221;bookmark&#8221; style=&#8221;display: inline-block; width: 0px; overflow: hidden; line-height: 0;&#8221; class=&#8221;mce_SELRES_start&#8221;&amp;gt;\ufeff&amp;lt;\/span&amp;gt;<\/iframe><\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1592155698727{background-color: #fff9f9 !important;}&#8221;][vc_column][vc_column_text]Pulsus bisferiens describes the presence of an exaggerated \u201cdouble pulsation\u201d in the arterial pulse. While the arterial pulse is normally dicrotic, consisting of a percussion wave and a tidal wave, the individual waves are not typically visible or palpable at the bedside. The pulse looks and feels<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":3164,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"page-templates\/page_PDXPDX-full-width.php","meta":{"nf_dc_page":"","_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"_lmt_disableupdate":"","_lmt_disable":"","footnotes":""},"class_list":["post-5894","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/pages\/5894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/comments?post=5894"}],"version-history":[{"count":0,"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/pages\/5894\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/pages\/3164"}],"wp:attachment":[{"href":"https:\/\/up.physicaldiagnosispdx.com\/up\/wp-json\/wp\/v2\/media?parent=5894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}